EGPK-95083N
Revised 11-01
Section 70
Installation Instructions for
Off-Equipment Mounting Kit #30000213
of Gear Oil Pressure Sender
(00-02-0212)
NOTE: The pressure hose must be capable of withstanding the
high pressure surges associated with operation of the gear. Use
of reinforced hose with crimped-on fittings is recommended.
NOTE: The pressure hose must NOT have a droop (low spot) in
its mounting. Water and sludge will collect in the droop and
prevent the pressure sender from operating.
WARNING
BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT
NOTE: Use of Teflon tape or non hardening thread sealant is
recommended.
✔ Disconnect all electrical power to the machine.
✔ Make sure the machine cannot operate during installation.
✔ Follow all safety warnings of the machine manufacturer.
✔ Read and follow all installation instructions.
CAUTION: Do not foul the pressure orifices with tape
or sealant.
Refer to diagram below.
CAUTION: This sender may be damaged by high
frequency vibration and/or high pressure spikes.
Mounting should be off equipment and isolated
through the shock mounts or other suitable methods.
1. Install the two (2) shock mounts onto the panel 30050782 and
secure with the 1/4-20 nuts provided. Mount panel off
equipment, if possible, and in a convenient location.
2. Install one PD2160 pressure snubber directly into the gear
pressure port and one onto the 1/8-27 NPT female end of the
customer supplied fitting. Fittings of various sizes are
available from Murphy.
Included in the 30000213 kit are the following:
• 1 ea. 30050782 Stainless steel panel
• 2 ea. 65000149 shock mounts
3. Install the customer supplied pressure hose onto the 1/8-27
NPT ends of the PD2160 pulsation snubbers.
4. Complete wiring according to instructions provided with the
pressure sender.
• 2 ea. PD2160 pressure snubber
• 1 ea. EGPK-95083N installation sheet
NOTE: Customer supplies a suitable pressure hose assembly
and fitting for connection into the gear pressure port. Murphy
can supply the hose and fitting upon request. Specify thread size
for gear pressure port and length of hose.
Satinless Steel Panel
30-05-0782
Pressure
Sender
Gear Casing
High Pressure Flexible Hose
(not included with the kit)
PD2160
PD2160
Gear
Pressure
Port
Mounting
Clamp
Correct
Incorrect
Shock
Mounts (2)
CONTROL SYSTEMS & SERVICES DIVISION
FRANK W. MURPHY, LTD.
MACQUARRIE CORPORATION
1620 Hume Highway
Campbellfield, Vic 3061; Australia
+61 3 9358 5555 fax +61 3 9358 5558
e-mail murphy@macquarrie.com.au
P.O. Box 1819; Rosenberg, Texas 77471; USA
+1 281 633 4500 fax +1 281 633 4588
e-mail sales@fwmurphy.com
Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.
+44 1722 410055 fax +44 1722 410088
e-mail sales@fwmurphy.co.uk
FW Murphy
P.O. Box 470248
MURPHY DE MEXICO, S.A. DE C.V.
Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje
San Luis Potosí, S.L.P.; México 78384
+52 444 8206264 fax +52 444 8206336
Villahermosa Office +52 993 3162117
e-mail ventas@murphymex.com.mx
MURPHY SWITCH OF CALIFORNIA
41343 12th Street West
Palmdale, California 93551-1442; USA
+1 661 272 4700 fax +1 661 947 7570
e-mail sales@murphyswitch.com
Tulsa, Oklahoma 74147 USA
+1 918 317 4100
fax +1 918 317 4266
e-mail sales@fwmurphy.com
USA–ISO 9001:2000 FM 28221
UK–ISO 9001:2000 FM 29422
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.
Printed in U.S.A.
|
Miele Convection Oven H 4894 BP2 User Manual
Miele Microwave Oven M 635 EG User Manual
Miller Electric Welder S 32S User Manual
MTD Snow Blower 769 04179 User Manual
Multiquip Drums MT 85H User Manual
NewAir Beverage Dispenser AW 280E User Manual
NordicTrack Home Gym NTW00630 User Manual
Onkyo DVD Player DV C503 User Manual
Onkyo Stereo System TX SR700 User Manual
Panasonic Air Conditioner CS PC18JKF User Manual